Universal meter with TRUE RMS function and automatic range for each measurement. It enables basic and advanced measurements of electrical quantities to be made. The large multifunctional LCD display, a range of functions to facilitate measurements, speed of operation and industrial precision will be appreciated by electronic engineers, electricians and home do-it-yourselfers alike. The housing is retrofitted with a red rubber holster with dedicated probe slots to prevent the meter from slipping easily from your hands and to minimise the risk of damage during a fall. The probe cables have silicone insulation that is flexible and resistant to high temperatures.
Basic measurements:
aC voltage measurement: A.C. 0-750V, TRUE RMS
dC voltage measurement: D.C. 0-1000V
aC current measurement: A.C. 0-19.999A, TRUE RMS
dC current measurement: D.C. 0-19.999A
resistance measurement: 0-9.999MΩ
diode test: IF 1.8mA,UR 3.2V
circuit continuity test: 0-50Ω
Additional measurements:
capacitor measurement: 0-9,999mF
frequency measurement: 0-9,999Mhz
filling factor measurement: 1-99%
Temperature measurement: -20 to 1000°C
non-contact AC voltage detection: NCV
MEASUREMENT ACCURACY
Example of accuracy determination for AC voltage measurement. Calculations for the measurement result: 235V
the measurement accuracy of the YT-730893 meter for this range is : ±(0.3% + 3), resolution 0.1V
calculation of measurement error formula: (measurement result x 0.3%) + 3 x resolution
calculations: (235 x 0.3%) + 3 x 0.1 = 0.705 + 0.3 = 1.005V
Actual result including measurement error for a 235V indication = 235 ± 1.005V
the result including the measurement error for the indication of the DC voltage measurement: 12V = 12 ± 0,009V
the result including the measurement error for the indication of the AC current measurement: 8A = 8 ± 0,067A
A table with the resolution and accuracy for a given measurement can be found in the operating instructions.
BUILT-IN FUNCTIONS
TRUE RMS - a meter with this function calculates the real rms value of AC voltage and current for both sinusoidal and non-sinusoidal waveforms. The device first measures the actual value of the sine wave over several time intervals → then squares the measurement results → adds them up → calculates the average → and finally roots the average result. The measurement result is the real rms value of the AC voltage/voltage even for a distorted sine wave or rectangular waveform
NCV - non-contact AC voltage detection by inductive method. The meter detects the presence of voltage in an insulated conductor using the NCV sensor on the face of the device
AUTO - automatic adjustment of the measuring range. When measuring unknown values using a meter with a manual range-changing dial, take measurements sequentially from the largest range up to the range giving the most accurate result - otherwise you risk damaging the instrument. With a multimeter with AUTO function, on the other hand, you only need to take one measurement and the meter will automatically find the optimum range. The meter starts by default in AUTO mode
RANGE - manual change of the measurement range. A useful function when checking many of the same components with a known value, e.g. a series of resistors. Manual setting of the range will reduce the time of such measurements considerably
REL - using the function during a measurement will reset the display to zero and take the value visible before the display as the reference level. The next measurement will show the difference between the measured value and the retained reference value
MAX/MIN - retaining on the display the maximum or minimum value from the current measurement
HZ % - when the knob is set to frequency measurement, the button will change the setting to fill factor/cycle measurement
SELECT - change of measurement mode, e.g. from AC to DC voltage measurement
DATA HOLD - keeping the currently measured value on the display
ADDITIONAL INFORMATION
lCD display, maximum displayed result: 19999
screen backlight
acoustic signal in the continuity test for resistances below 50Ω
possibility to include diode and continuity tests separately
measuring probes 14.5 cm long
length of cable including probes: 97 cm
cable diameter including insulation: 3.5 mm
immersion probe for temperature measurement
design with overload protection
aBS plastic housing
automatic shutdown of the meter after 15 minutes of inactivity
possibility to switch off the automatic switch-off mode
Available Delivery Methods: Pickup at Latvijas Pasts branch, Courier delivery to home — Express Pasts, Pickup from our warehouse, Daugavpils
Bank Transfer (Invoice)
Pay at any bank.
Available Delivery Methods: Pickup at Latvijas Pasts branch, Pickup at Omniva parcel locker, Courier delivery to home — Express Pasts, Pickup from our warehouse, Daugavpils
Online Payment (i-Bank)
Pay conveniently and quickly via internet banking: Swedbank, SEB, LPB, Luminor, Citadele, Revolut, Rietumu, N26, Paysera, Wise
Available Delivery Methods: Pickup at Latvijas Pasts branch, Pickup at Omniva parcel locker, Courier delivery to home — Express Pasts, Pickup from our warehouse, Daugavpils
Bank Card
Pay with a bank card upon delivery.
Available Delivery Methods: Pickup at Latvijas Pasts branch, Courier delivery to home — Express Pasts